Skip to main content

Setup Configuration

Once a Terminal-instance has been created with a TerminalSettings-instance, the settings can not be changed anymore. Changes to the TerminalSettings-instance will be ignored.

The network and guides configuration are explained in the following chapters. For further information refer toTerminalSettings.

Network Configuration​

Depending on the platform used, the TIM API module can communicate with the Terminal over different communication channels.

The default communication is over TCP/IP connection. Default port used is 7784.

On mobile devices also a Bluetooth connection is possible.

For TCP/IP connection there are two possible ways to connect to the terminal:

  * **Broadcast-Mode:**
* Terminal ID (TID) is known.
* The TIM API starts broadcasting on the default interface and connects to the connection information sent by the matching terminal.
* **Direct Connect:**
* IP address of the terminal is known.
* Connection is established directly via IP.

Guides Configuration​

There are various Guides covering different use case scenarios. The guide Retailis the basic guide and is activated as default. With .guides the guides can be configured. Important: the configuration needs to include all desired guides (including the retail guide).

Code-example for creating a terminal including settings with activated guides retail and hospitality:

// Create settings with Terminal-ID of terminal to connect to
let terminalSettings = try TerminalSettings()
terminalSettings.terminalId = "12345678"
// add wanted guides (with insert)
terminalSettings.guides.insert(CGuides.retail)
terminalSettings.guides.insert(CGuides.hospitality)
// Create terminal
var terminal = try Terminal(settings: terminalSettings)
//...

// Disconnect from terminal and clean up properly
terminal.dispose()